Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Food Environ Virol ; 13(3): 303-315, 2021 09.
Article in English | MEDLINE | ID: covidwho-1321887

ABSTRACT

Wastewater surveillance of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is an emerging public health tool to understand the spread of Coronavirus Disease 2019 (COVID-19) in communities. The performance of different virus concentration methods and PCR methods needs to be evaluated to ascertain their suitability for use in the detection of SARS-CoV-2 in wastewater. We evaluated ultrafiltration and polyethylene glycol (PEG) precipitation methods to concentrate SARS-CoV-2 from sewage in wastewater treatment plants and upstream in the wastewater network (e.g., manholes, lift stations). Recovery of viruses by different concentration methods was determined using Phi6 bacteriophage as a surrogate for enveloped viruses. Additionally, the presence of SARS-CoV-2 in all wastewater samples was determined using reverse transcription quantitative PCR (RT-qPCR) and reverse transcription droplet digital PCR (RT-ddPCR), targeting three genetic markers (N1, N2 and E). Using spiked samples, the Phi6 recoveries were estimated at 2.6-11.6% using ultrafiltration-based methods and 22.2-51.5% using PEG precipitation. There was no significant difference in recovery efficiencies (p < 0.05) between the PEG procedure with and without a 16 h overnight incubation, demonstrating the feasibility of obtaining same day results. The SARS-CoV-2 genetic markers were more often detected by RT-ddPCR than RT-qPCR with higher sensitivity and precision. While all three SARS-CoV-2 genetic markers were detected using RT-ddPCR, the levels of E gene were almost below the limit of detection using RT-qPCR. Collectively, our study suggested PEG precipitation is an effective low-cost procedure which allows a large number of samples to be processed simultaneously in a routine wastewater monitoring for SARS-CoV-2. RT-ddPCR can be implemented for the absolute quantification of SARS-CoV-2 genetic markers in different wastewater matrices.


Subject(s)
Chemical Fractionation/methods , SARS-CoV-2/isolation & purification , Ultrafiltration/methods , Wastewater/chemistry , Wastewater/virology , Chemical Precipitation , Environmental Monitoring , Polyethylene Glycols/chemistry , Public Health , Reverse Transcriptase Polymerase Chain Reaction/methods , SARS-CoV-2/genetics , Sewage/chemistry , Sewage/virology , Viral Proteins/genetics , Water Pollution/analysis
2.
Curr Protoc ; 1(4): e130, 2021 Apr.
Article in English | MEDLINE | ID: covidwho-1202693

ABSTRACT

The most common method for RNA detection involves reverse transcription followed by quantitative polymerase chain reaction (RT-qPCR) analysis. Commercial one-step master mixes-which include both a reverse transcriptase and a thermostable polymerase and thus allow performing both the RT and qPCR steps consecutively in a sealed well-are key reagents for SARS-CoV-2 diagnostic testing; yet, these are typically expensive and have been affected by supply shortages in periods of high demand. As an alternative, we describe here how to express and purify Taq polymerase and M-MLV reverse transcriptase and assemble a homemade one-step RT-qPCR master mix. This mix can be easily assembled from scratch in any laboratory equipped for protein purification. We also describe two simple alternative methods to prepare clinical swab samples for SARS-CoV-2 RNA detection by RT-qPCR: heat-inactivation for direct addition, and concentration of RNA by isopropanol precipitation. Finally, we describe how to perform RT-qPCR using the homemade master mix, how to prepare in vitro-transcribed RNA standards, and how to use a fluorescence imager for endpoint detection of RT-PCR amplification in the absence of a qPCR machine In addition to being useful for diagnostics, these versatile protocols may be adapted for nucleic acid quantification in basic research. © 2021 The Authors. Current Protocols published by Wiley Periodicals LLC. Basic Protocol 1: Preparation of a one-step RT-qPCR master mix using homemade enzymes Basic Protocol 2: Preparation of swab samples for direct RT-PCR Alternate Protocol 1: Concentration of RNA from swab samples by isopropanol precipitation Basic Protocol 3: One-step RT-qPCR of RNA samples using a real-time thermocycler Support Protocol: Preparation of RNA concentration standards by in vitro transcription Alternate Protocol 2: One-step RT-PCR using endpoint fluorescence detection.


Subject(s)
COVID-19 Nucleic Acid Testing/methods , COVID-19/diagnosis , RNA, Viral/isolation & purification , SARS-CoV-2/isolation & purification , COVID-19/virology , COVID-19 Nucleic Acid Testing/economics , Chemical Precipitation , Humans , RNA, Viral/genetics , SARS-CoV-2/genetics , Time Factors
3.
PLoS One ; 16(2): e0246647, 2021.
Article in English | MEDLINE | ID: covidwho-1060986

ABSTRACT

Re-opening of communities in the midst of the ongoing COVID-19 pandemic has ignited new waves of infections in many places around the world. Mitigating the risk of reopening will require widespread SARS-CoV-2 testing, which would be greatly facilitated by simple, rapid, and inexpensive testing methods. This study evaluates several protocols for RNA extraction and RT-qPCR that are simpler and less expensive than prevailing methods. First, isopropanol precipitation is shown to provide an effective means of RNA extraction from nasopharyngeal (NP) swab samples. Second, direct addition of NP swab samples to RT-qPCRs is evaluated without an RNA extraction step. A simple, inexpensive swab collection solution suitable for direct addition is validated using contrived swab samples. Third, an open-source master mix for RT-qPCR is described that permits detection of viral RNA in NP swab samples with a limit of detection of approximately 50 RNA copies per reaction. Quantification cycle (Cq) values for purified RNA from 30 known positive clinical samples showed a strong correlation (r2 = 0.98) between this homemade master mix and commercial TaqPath master mix. Lastly, end-point fluorescence imaging is found to provide an accurate diagnostic readout without requiring a qPCR thermocycler. Adoption of these simple, open-source methods has the potential to reduce the time and expense of COVID-19 testing.


Subject(s)
COVID-19/diagnosis , RNA, Viral/analysis , Real-Time Polymerase Chain Reaction/methods , SARS-CoV-2/genetics , COVID-19/virology , COVID-19 Nucleic Acid Testing , Chemical Precipitation , Coronavirus Nucleocapsid Proteins/genetics , Humans , Limit of Detection , Nasopharynx/virology , Phosphoproteins/genetics , RNA, Viral/isolation & purification , RNA, Viral/metabolism , SARS-CoV-2/isolation & purification
4.
Int J Hyg Environ Health ; 233: 113692, 2021 04.
Article in English | MEDLINE | ID: covidwho-1056688

ABSTRACT

The aim of the present study was to develop a simple, sensitive, and specific approach to quantifying the SARS-CoV-2 genome in wastewater and to evaluate this approach as a means of epidemiological surveillance. Twelve wastewater samples were collected from a metropolitan area in north-eastern France during April and May 2020. In addition to the quantification of the SARS-CoV-2 genome, F-specific RNA phages of genogroup II (FRNAPH GGII), naturally present in wastewater, were used as an internal process control for the viral concentration and processing of RT-PCR inhibitors. A concentration method was required to allow the quantification of the SARS-CoV-2 genome over the longest possible period. A procedure combining ultrafiltration, phenol-chloroform-isoamyl alcohol purification, and the additional purification of the RNA extracts was chosen for the quantification of the SARS-CoV-2 genome in 100-mL wastewater samples. At the same time, the COVID-19 outbreak was evaluated through patients from the neighbouring University Hospital of Nancy, France. A regular decrease in the concentration of the SARS-CoV-2 genome from ~104 gc/L to ~102 gc/L of wastewater was observed over the eight weeks of the study, during which the population was placed under lockdown. The SARS-CoV-2 genome was even undetectable during one week in the second half of May and present but non-quantifiable in the last sample (28 May). A concordant circulation in the human community was highlighted by virological diagnosis using respiratory samples, which showed a decrease in the number of COVID-19 cases from 677 to 52 per week over the same period. The environmental surveillance of COVID-19 using a reliable viral quantification procedure to test wastewater is a key approach. The real-time detection of viral genomes can allow us to predict and monitor the circulation of SARS-CoV-2 in clinical settings and survey the entire urban human population.


Subject(s)
COVID-19/epidemiology , Disease Outbreaks , Environmental Monitoring/methods , Genome, Viral , SARS-CoV-2/genetics , Wastewater/microbiology , COVID-19/diagnosis , COVID-19/virology , Chemical Precipitation , Cities/epidemiology , France/epidemiology , Hospitals, University , Humans , Ultrafiltration , Viral Proteins/chemistry , Viral Proteins/isolation & purification , Water Microbiology
5.
Adv Clin Chem ; 104: 299-340, 2021.
Article in English | MEDLINE | ID: covidwho-893387

ABSTRACT

Cryoglobulins consist of serum immunoglobulins that precipitate below 37°C and resolubilize upon warming. The clinical triad of cryoglobulinemia usually includes purpura, weakness, and arthralgia. Cryoglobulinemic syndrome, clinically defined as a systemic vasculitis, is associated with chronic infection with hepatitis C virus (HCV) and autoimmune disorders and can evolve into B-cell malignancies. While the current literature about HCV-associated cryoglobulinemia is not very limited, little is known about the immunologic and serologic profiles of affected patients. Therefore, comprehension of the pathogenetic mechanisms underlying cryoprecipitation could be very helpful. Due to the persistence of viral antigenic stimulation, biomarkers to use after the worsening progression of HCV infection to lymphoproliferative and/or autoimmune diseases are widely needed. Laboratory methods used to detect and characterize low concentrations of cryoprecipitates and immunotyping patterns could improve patient management. The most critical factor affecting cryoglobulin testing is that the pre-analytical phase is not fully completed at 37°C.


Subject(s)
Biomarkers/blood , COVID-19/complications , Cryoglobulinemia/blood , Cryoglobulins/analysis , Hepatitis C/physiopathology , Animals , Autoantibodies/blood , Chemical Precipitation , Cryoglobulinemia/therapy , Cryoglobulins/chemistry , Hepatitis C/blood , Humans , Vasculitis/virology
SELECTION OF CITATIONS
SEARCH DETAIL